Try the full study dashboard free, no signup: practice, flashcards and your Exam Readiness Score. Open it →
Home / Practice tests / ASNT IRRSP Combo (RAM/XR)
ASNT · Last updated November 2026

ASNT IRRSP, Combination (Radioactive Materials and X-ray): free practice test

ASNT's combined radiation safety credential for radiographers who use both sealed gamma sources and X-ray machines: one 100-item, 3-hour computer-based exam at a 70% minimum score. Applicants document 200 hours (29 days) of RAM experience, 120 hours (18 days) of X-ray experience and 40 hours (6 days) of radiation safety training on the 10 CFR 34.43(g) topics. This prep covers only the written exam; the visual acuity and practical exams are given by your employer, and the practical forms are due within six months of the exam.

Watch the free 4:07 video lesson: the key ASNT IRRSP Combo (RAM/XR) concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free ASNT IRRSP Combo (RAM/XR) study dashboard: flashcards, notes and your Readiness Score, no signup →

About the ASNT IRRSP Combo (RAM/XR) exam

ASNT's combined radiation safety credential for radiographers who use both sealed gamma sources and X-ray machines: one 100-item, 3-hour computer-based exam at a 70% minimum score. Applicants document 200 hours (29 days) of RAM experience, 120 hours (18 days) of X-ray experience and 40 hours (6 days) of radiation safety training on the 10 CFR 34.43(g) topics. This prep covers only the written exam; the visual acuity and practical exams are given by your employer, and the practical forms are due within six months of the exam.

What's on the exam

ASNT IRRSP Combo (RAM/XR)
Fundamentals of Radiation Safety
7 key facts
Exposure and Biological Effects
6 key facts
Controlling Exposure: Time, Distance and Shielding
6 key facts
Radiation Detection and Personnel Monitoring
6 key facts
Radiographic Equipment: Exposure Devices and X-ray Machines
7 key facts
Regulations: NRC, Agreement State and SSRCR Rules
8 key facts
Operating and Emergency Procedures
6 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the ASNT IRRSP Combo (RAM/XR) exam

  • Keep the gamma and X-ray rules apart. The alarming ratemeter is required for sealed source work but not, under SSRCR Part E, for radiation machines.
  • One exam covers both source types in the same 100 items and 3 hours, so practice switching quickly between half-life sums and kV or mA questions.
  • Combo candidates must submit both a RAM and an X-ray practical form to be certified for both; a missing form limits your certificate to one method.
  • Regulations has the longest list of subtopics. Memorize the intervals in 10 CFR Part 34: 6 months for meters and leak tests, 3 months for inventory and inspection, 12 months for refresher training.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the NDT Level III Formula Sheet.

Take the test first

What's in the premium ASNT IRRSP Combo (RAM/XR) prep

Premium ASNT IRRSP Combo (RAM/XR) prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 100 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 7 topics

Your step-by-step study path

  1. 1
    Fundamentals of Radiation Safety9 key notes, 115 flashcards, then 450 practice questions in 18 sets of 25
    Notes free with an account
  2. 2
    Exposure and Biological Effects9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  3. 3
    Controlling Exposure: Time, Distance and Shielding9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  4. 4
    Radiation Detection and Personnel Monitoring9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  5. 5
    Radiographic Equipment: Exposure Devices and X-ray Machines8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  6. 6
    Regulations: NRC, Agreement State and SSRCR Rules8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  7. 7
    Operating and Emergency Procedures8 key notes, 110 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  8. Final step: 6 full mock exams100 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete ASNT IRRSP Combo (RAM/XR) study notes for “Fundamentals of Radiation Safety”

Our first full set of comprehensive notes, about 15 minutes of reading: Gamma sources and decay · X-ray tubes · Gamma versus X-ray safety differences · Interactions with matter · Units, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. A radiographer's Ir-192 source measures 96 Ci today, and the source's half-life is taken as 74 days. What activity remains after 222 days?
Answer: 12 Ci. 222 days is 3 half-lives (222 / 74), so the activity halves three times: 96 to 48, then 24, then 12 Ci. Answering 32 Ci divides by 3 instead of halving three times. Count half-lives first, then halve that many times.
2. A power failure hits a job where an X-ray tube is energized and an Ir-192 source is cranked out in a second area. What is the radiation status of the two sources?
Answer: The tube stops producing X rays, but the exposed Ir-192 source keeps emitting. An X-ray tube needs electrical power to produce radiation, so a power failure stops it. A sealed gamma source emits continuously and depends only on shielding, so the exposed source still needs to be cranked back and verified by survey. This difference drives every emergency plan on a mixed job.
3. A radiographer receives an estimated whole-body dose of 25 rem in a brief accident. Which outcome is most likely?
Answer: No clinical symptoms, with a possible detectable blood count change. A whole-body dose of 25 rem is generally below the range that causes clinical acute radiation syndrome, although blood changes may be detectable. Vomiting and hair loss appear at doses in the hundreds of rem, and marrow death at higher levels. A 25 rem TEDE event still triggers immediate notification under 10 CFR 20.2202.
4. A 17-year-old is hired to help in a radiography shop, away from exposure devices. What annual TEDE limit applies to this worker's occupational exposure?
Answer: 0.5 rem. Occupational limits for minors are 10 percent of the adult limits, so the TEDE limit is 0.5 rem (5 mSv) per year. Answering 5 rem applies the adult limit, while 0.1 rem is the limit for a member of the public. Age, not job title, decides which limit applies.
5. Using a dose rate factor of 5.2 R/h per Ci at 1 ft for Ir-192, what is the rate at 40 ft from an exposed 20 Ci source, with no shielding?
Answer: 65 mR/h. At 1 ft, the rate is 5.2 x 20 = 104 R/h, and inverse square at 40 ft divides by 40 squared (1,600), giving 0.065 R/h or 65 mR/h. Answering 260 mR/h comes from using 20 ft instead of 40 ft, which is the source strength misread as the distance. Always convert the final answer from R/h to mR/h.
6. A vault wall must reduce a Co-60 rate from 1,000 mR/h to 1 mR/h. If the tenth-value layer of the concrete is taken as 8 in., what thickness is required?
Answer: 24 in.. 1,000 to 1 is a factor of 1,000, which is three tenth-value layers (10 x 10 x 10), so 3 x 8 in. = 24 in. A 16 in. wall is only two tenth-value layers and would still leave 10 mR/h. A tenth-value layer cuts the rate by 10, so count the powers of ten.
7. A radiographer alternates between Ir-192 shots and shots with an X-ray machine at the same field site. Under 10 CFR 34.47 and SSRCR Part E, how do the alarming ratemeter rules apply?
Answer: Required during Ir-192 work, but not required during X-ray machine work. A worker using sealed sources must wear an operating alarming ratemeter set to alarm at 500 mR/h, except at permanent installations with other alarms in routine use. SSRCR Part E exempts radiographic operations using radiation machines, because such machines are unlikely to reach the alarm level. A pocket dosimeter does not replace the ratemeter for gamma work.
8. A survey meter has a highest range of 500 mR/h and a calibration sticker dated three months ago. Can it be used as the required survey instrument at a radiography job?
Answer: No, its range must extend through 1 R/h. A required survey instrument must measure from 2 mR/h through 1 R/h, so a 500 mR/h ceiling fails even with a valid calibration. The calibration interval is up to 6 months, so the sticker date is fine, but range is a separate requirement. A ratemeter cannot substitute for the survey meter.
9. A source changer holding an Ir-192 source measures 150 mrem/h at the surface and 18 mrem/h at 1 meter, with the source in the shielded position. Does it comply with 10 CFR 34.21?
Answer: No, the 1 meter reading exceeds the limit of 10 mrem/h. The limits for storage containers and source changers are 200 mrem/h at any exterior surface and 10 mrem/h at 1 meter. The surface reading passes, but 18 mrem/h at 1 meter exceeds the limit. Check both limits: passing one does not clear the container.
10. A leak test on a sealed Ir-192 source shows 0.01 microcurie of removable contamination. What must the licensee do under 10 CFR 34.27?
Answer: Withdraw the equipment from use immediately and file the required report. A result of 0.005 microcurie (185 Bq) or more is evidence of a leaking source, so the equipment must be withdrawn immediately, decontaminated and repaired or disposed of, and a report filed. Continuing use because the number looks small uses the wrong threshold. Leak tests are due at intervals not over 6 months.
11. A radiographer returns after 7 months away from radiographic work, and the last job-performance inspection was 8 months ago. What does 10 CFR 34.43(e) require before the radiographer next takes part in radiography?
Answer: Demonstrate knowledge by a practical examination. If a radiographer has not taken part in radiography for more than 6 months since the last inspection, the training requirements must be demonstrated by a practical examination before the next radiographic operation. Refresher training is a separate 12-month requirement. The rule tests hands-on knowledge after a gap.
12. A package of Ir-192 measures 40 mrem/h at its surface and 1.5 mrem/h at 1 meter. Which DOT radioactive label is required under 49 CFR?
Answer: Yellow-III. The surface rate alone would fit Yellow-II, but the transport index of 1.5 is above the Yellow-II ceiling of 1.0, so Yellow-III is required. White-I stops at 0.5 mrem/h at the surface. Check both the surface rate and the transport index, because the higher category controls.
13. On Monday morning, the audible and visible alarm at a permanent radiographic installation fails its daily test. What may the licensee do?
Answer: Tag it defective, repair within 7 calendar days, and use continuous surveillance with an alarming ratemeter meanwhile. A failed alarm or entrance control must be labeled defective at once and repaired within 7 calendar days. Use may continue during those days only with continuous direct visual surveillance and an alarming ratemeter. Locked doors alone do not replace the alarm system.
14. During an Ir-192 exposure, the source will not return when cranked, and the survey meter reads high along the guide tube. What should the crew do first?
Answer: Secure and post a larger boundary, keep surveillance, and notify the RSO. A source that will not retract is an emergency, so the crew should keep people out, enlarge and post the boundary as needed, maintain surveillance and contact the RSO. Recovery is carried out only by trained, authorized people under an approved plan with dose control. Handling the guide tube or disconnecting the cable puts people close to an unshielded source.
15. After an Ir-192 exposure, the radiographer cranks the source back and the lock engages. What must be done before changing the film?
Answer: Survey the device and the full guide tube on approach. A survey of the device and the guide tube is required after each exposure, when approaching the equipment, to determine that the source has returned to its shielded position. A boundary reading or a dosimeter reading cannot prove the source is shielded. A locked crank does not prove it either, because the source can stay in the tube.

Get the full ASNT IRRSP Combo (RAM/XR) prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a retake fee, for the certification that lets you approve procedures and certify technicians
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

ASNT IRRSP Combo (RAM/XR) exam FAQ

How many questions are on the ASNT IRRSP Combo (RAM/XR) exam?

100 multiple-choice items covering radioactive materials and X-ray, with a time limit of 3 hours. Format: computer-based multiple choice. asnt does not publish whether references are supplied during the exam; confirm with asnt. asnt directs candidates to a calculator demo before the exam. this prep covers only the written exam, not the employer's visual acuity and practical exams.

What is the passing score for ASNT IRRSP Combo (RAM/XR)?

Minimum score of 70% (ASNT-CP-IRRSP 2020 Edition). Both a RAM and an X-ray practical are needed; if only one is submitted, certification is issued only for that method.

How much does the ASNT IRRSP Combo (RAM/XR) exam cost?

US$300 for ASNT members, US$325 for nonmembers. Retake of a failed exam: US$260 / US$285. Recertification by exam every five years: US$300 / US$325. ASNT fees differ for members and nonmembers and can change, so confirm on the ASNT certification website before you apply.

Which languages is the ASNT IRRSP Combo (RAM/XR) exam offered in?

English (ASNT offers an online NDT terminology dictionary in Korean, Mandarin, Spanish, UK English and Arabic).

Where do I take the ASNT IRRSP Combo (RAM/XR) exam?

Pearson VUE test centers and ASNT Authorized Exam Centers (in person, computer-based), scheduled through MyCert after application approval.

Is this ASNT IRRSP Combo (RAM/XR) practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full ASNT IRRSP Combo (RAM/XR) prep is Premium at $147 a month for this exam.

What's in the premium ASNT IRRSP Combo (RAM/XR) prep?

3,000 practice questions organized topic by topic (Fundamentals of Radiation Safety: 450; Exposure and Biological Effects: 425; Controlling Exposure: Time, Distance and Shielding: 425; Radiation Detection and Personnel Monitoring: 425; Radiographic Equipment: Exposure Devices and X-ray Machines: 425; Regulations: NRC, Agreement State and SSRCR Rules: 425; Operating and Emergency Procedures: 425), 6 full-length timed mock exams of 100 questions, 800 flashcards and 60 comprehensive key notes split across all 7 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in October 2026. ASNT changes formats and fees, so confirm with ASNT Certification Services LLC (American Society for Nondestructive Testing) before you book. NDTLevel3Exam is not affiliated with ASNT or Pearson VUE.

Start the free test