Try the full study dashboard free, no signup: practice, flashcards and your Exam Readiness Score. Open it →
Home / Practice tests / IR Thermography Level III
ASNT · Last updated November 2026

ASNT NDT Level III Infrared and Thermal Testing (IR): free practice test

The ASNT Level III thermal/infrared method exam: 90 questions in 2 hours on heat transfer principles, temperature measurement equipment, contact and noncontact techniques, interpretation and evaluation, procedures, and safety. IR is not one of ASNT's ANAB-accredited Level III methods.

Watch the free 4:11 video lesson: the key IR Thermography Level III concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free IR Thermography Level III study dashboard: flashcards, notes and your Readiness Score, no signup →

About the IR Thermography Level III exam

The ASNT Level III thermal/infrared method exam: 90 questions in 2 hours on heat transfer principles, temperature measurement equipment, contact and noncontact techniques, interpretation and evaluation, procedures, and safety. IR is not one of ASNT's ANAB-accredited Level III methods.

What's on the exam

IR Thermography Level III
Principles and Theory of Heat Transfer
7 key facts
Equipment and Materials
7 key facts
Thermal and Infrared Techniques
8 key facts
Interpretation and Evaluation
7 key facts
Procedures and Standards
6 key facts
Safety and Health
6 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the IR Thermography Level III exam

  • 90 questions in 2 hours is 80 seconds each. Keep the Stefan-Boltzmann, Wien, Fourier and spot-size arithmetic short.
  • Always convert to kelvin before using T⁴ or Wien's law. A Celsius value in either formula gives a wrong but tempting answer.
  • For every measurement question, check emissivity, reflected apparent temperature, transmission (windows, atmosphere) and spot size before trusting a number.
  • ASNT's techniques list is organized by investigation type: exothermic or endothermic, friction, fluid flow, thermal resistance and thermal capacitance. Know an application for each.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the NDT Level III Formula Sheet.

Take the test first

What's in the premium IR Thermography Level III prep

Premium IR Thermography Level III prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 90 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 6 topics

Your step-by-step study path

  1. 1
    Principles and Theory of Heat Transfer10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Notes free with an account
  2. 2
    Equipment and Materials10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  3. 3
    Thermal and Infrared Techniques10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  4. 4
    Interpretation and Evaluation10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  5. 5
    Procedures and Standards10 key notes, 130 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  6. 6
    Safety and Health10 key notes, 130 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  7. Final step: 6 full mock exams90 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete IR Thermography Level III study notes for “Principles and Theory of Heat Transfer”

Our first full set of comprehensive notes, about 15 minutes of reading: Heat, temperature and heat flow · Conduction and convection · Radiation · Choosing thermal/infrared testing, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. At about what wavelength does a blackbody at 27 °C emit most strongly?
Answer: About 9.7 µm. Wien's displacement law: λmax = 2898 µm·K ÷ T. At 300 K, λmax ≈ 9.7 µm, which is why long-wave (8 to 14 µm) cameras suit near-ambient targets. Using 27 instead of 300 K gives 107 µm.
2. A 0.10 m thick insulation layer with thermal conductivity 0.04 W/(m·K) has a steady 30 K difference across it. What is the heat flux?
Answer: 12 W/m². Fourier's law for steady conduction: q = k × ΔT ÷ L = 0.04 × 30 ÷ 0.10 = 12 W/m². Multiplying by thickness instead of dividing gives 0.12 W/m².
3. Two surfaces have the same emissivity, one at 127 °C and one at 27 °C. About how many times more radiant power per unit area does the hotter one emit?
Answer: About 3.2 times. Stefan-Boltzmann: W = εσT⁴ with T in kelvin. (400 ÷ 300)⁴ = 3.16. The ratio of Celsius values (127 ÷ 27 = 4.7) or the linear kelvin ratio (1.3) are the usual mistakes.
4. A camera has an IFOV of 1.5 mrad. At 8 m, what is the smallest target it can measure accurately if the measurement spot must be 3 times the IFOV footprint?
Answer: About 36 mm. IFOV footprint = 1.5 × 10⁻³ rad × 8000 mm = 12 mm. Three pixels across gives about 36 mm for a reliable temperature reading. A 12 mm target is detectable but its temperature will read low (spatial averaging).
5. A two-color (ratio) pyrometer is chosen to measure a hot steel bar seen through steam and dust. What is the reason?
Answer: Partial obscuration and graybody emissivity largely cancel in the ratio of two bands. A ratio pyrometer compares radiance in two nearby wavebands. If the target is a graybody and the path attenuates both bands equally, these effects cancel. It still errs on selective emitters whose emissivity differs between the bands.
6. A thermographer tries to inspect an energized panel through an ordinary glass window using an 8 to 14 µm camera. What will the image show?
Answer: Mainly the glass surface and its reflections. Ordinary glass is essentially opaque in the long-wave band, so the camera sees the glass surface and reflections, not the panel. Use an infrared window of suitable material with a known transmission, or open the panel under arc flash controls.
7. In pulsed thermography of a composite panel, a delamination 1 mm deep shows best contrast at about 0.5 s. When would a similar delamination 3 mm deep show?
Answer: About 4.5 s. In transient thermography the observation time scales with depth squared over thermal diffusivity. Three times deeper means about 9 times longer: 0.5 × 9 = 4.5 s, with less contrast. Scaling linearly with depth gives 1.5 s.
8. During a morning warm-up, a thermal image of an outdoor storage tank shows a sharp horizontal line at the liquid level. Which investigation type is this?
Answer: Thermal capacitance: the liquid warms more slowly. The liquid has much higher heat capacity than the vapor space, so the shell next to it lags behind during heating or cooling. Imaging during a transient makes levels of liquid, sludge or foam visible. In steady conditions the line can disappear.
9. An exterior survey is planned to find missing wall insulation in a heated building. Which conditions are best?
Answer: Steady inside-outside ΔT, no sun on the walls for hours, low wind. Missing insulation shows by thermal resistance, which needs steady heat flow driven by an inside-outside temperature difference (ASTM C1060 suggests at least 10 °C). Solar loading and wind create patterns unrelated to insulation; moisture adds evaporative cooling that confuses the image.
10. A shiny bare-copper bolted joint reads colder than the painted parts around it, though it carries the same current. What is the most likely explanation?
Answer: Its low emissivity makes the camera read it low. Polished metal has low emissivity and high reflectivity, so it emits little and reflects its surroundings, giving a low and unreliable reading. Measure on a high-emissivity spot such as paint or tape, or compare similar components, rather than trusting the bare metal value.
11. A connection reads 12 °C above the matching phase on a feeder carrying only 20% of rated load. What is the best evaluation?
Answer: Serious: I²R heating will rise sharply with load. Resistive heating rises roughly with current squared, so a 12 °C rise at 20% load may become many times larger at full load. Report it as potentially serious and recheck under higher load (NFPA 70B and ASTM E1934 call for adequate load). Applying a fixed ΔT table without load correction understates it.
12. A surface with emissivity 0.3 is being measured near a hot furnace wall. Besides emissivity, which parameter must be set correctly for an accurate reading?
Answer: Reflected apparent temperature. A low-emissivity surface reflects 70% of the radiance it receives, here from the hot wall, so the camera must know the reflected apparent temperature (measured per ASTM E1862) to subtract it. Palette and span change only the display.
13. A procedure needs a standard test method for measuring and compensating for emissivity using a reference material of known emissivity. Which standard applies?
Answer: ASTM E1933. ASTM E1933 covers measuring and compensating for emissivity with infrared imaging radiometers. E1862 covers reflected temperature, E1934 covers examining electrical and mechanical equipment, and C1060 covers building envelope insulation surveys.
14. A thermographer must open an energized 480 V switchboard cover to scan the bus. What governs the protective equipment required?
Answer: An arc flash risk assessment under NFPA 70E or equivalent. Removing covers from energized equipment exposes the worker to arc flash and shock. NFPA 70E (in the US) requires a risk assessment that sets approach boundaries and PPE. ASTM E1934 tells you how to inspect, not how to protect yourself.
15. A thermographer will do a night-time roof moisture survey on a flat commercial roof. What is the main safety hazard to plan for?
Answer: Falls at edges, skylights and openings. Night roof surveys combine darkness, edges, unguarded skylights and soft wet insulation, so fall protection and a lit, planned route are essential. The roof emits harmless long-wave radiation, and class 2 laser pointers are a minor hazard by comparison.

Get the full IR Thermography Level III prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a retake fee, for the certification that lets you approve procedures and certify technicians
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

IR Thermography Level III exam FAQ

How many questions are on the IR Thermography Level III exam?

90 multiple-choice questions, with a time limit of 2 hours. Format: closed book, computer-based, with an on-screen calculator. no practical exam. you must also pass the ndt basic exam to be certified.

What is the passing score for IR Thermography Level III?

Not published per exam. Aim for 80% or higher in practice (ASNT says its criterion-referenced cut scores are typically 70% to 80%).

How much does the IR Thermography Level III exam cost?

US$525 for ASNT members, US$605 for nonmembers (retake US$455 / US$535). ASNT fees differ for members and nonmembers and can change, so confirm on the ASNT certification website before you apply.

Which languages is the IR Thermography Level III exam offered in?

English (an online NDT terminology translation dictionary is available).

Where do I take the IR Thermography Level III exam?

Pearson VUE test centers and ASNT Authorized Exam Centers (in person, computer-based).

Is this IR Thermography Level III practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full IR Thermography Level III prep is Premium at $147 a month for this exam.

What's in the premium IR Thermography Level III prep?

3,000 practice questions organized topic by topic (Principles and Theory of Heat Transfer: 500; Equipment and Materials: 500; Thermal and Infrared Techniques: 500; Interpretation and Evaluation: 500; Procedures and Standards: 500; Safety and Health: 500), 6 full-length timed mock exams of 90 questions, 800 flashcards and 60 comprehensive key notes split across all 6 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in October 2026. ASNT changes formats and fees, so confirm with ASNT Certification Services LLC (American Society for Nondestructive Testing) before you book. NDTLevel3Exam is not affiliated with ASNT or Pearson VUE.

Start the free test