The exam at a glance
| Questions | 90 multiple-choice questions |
|---|---|
| Time | 2 hours |
| Passing score | Not published per exam. Aim for 80% or higher in practice (ASNT says its criterion-referenced cut scores are typically 70% to 80%) |
| Format | Closed book, computer-based, with an on-screen calculator. No practical exam. You must also pass the NDT Basic exam to be certified |
| Certifying body | ASNT Certification Services LLC (American Society for Nondestructive Testing) |
| Test provider | Pearson VUE test centers and ASNT Authorized Exam Centers (in person, computer-based) |
Mind map: the whole exam on one screen
Read the complete IR Thermography Level III study notes for “Principles and Theory of Heat Transfer”
Our first full set of comprehensive notes, about 15 minutes of reading: Heat, temperature and heat flow · Conduction and convection · Radiation · Choosing thermal/infrared testing, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.
1. Principles and Theory of Heat Transfer
Conduction, convection and radiation, the nature of heat and heat flow, temperature measurement principles and when to choose thermal/infrared testing. ASNT does not publish domain weights for the IR exam.
Key facts
- Heat moves from hot to cold by conduction (within solids and still fluids), convection (by moving fluid) and radiation (electromagnetic, needs no medium).
- Fourier's law: q = k × ΔT ÷ L for steady conduction through a layer; thermal resistance R = L ÷ k.
- Newton's law of cooling: q = h × ΔT; natural convection h is a few W/(m²·K), forced convection much higher.
- Stefan-Boltzmann: W = εσT⁴, σ = 5.67 × 10⁻⁸ W/(m²·K⁴), T in kelvin.
- Wien's law: λmax = 2898 µm·K ÷ T. Near-ambient objects peak around 10 µm; hotter objects peak at shorter wavelengths.
- Kirchhoff: at equilibrium emissivity equals absorptivity. Energy balance: ε + ρ + τ = 1; for opaque bodies ε + ρ = 1.
- Choose IR when a defect or condition changes heat flow or surface temperature; it shows surface temperature only and needs heat flow to work.
Flashcards
Exam tip: Convert to kelvin first, then decide which law applies: conduction through it, convection off it, or radiation from it.
2. Equipment and Materials
Temperature measurement equipment, contact devices, noncontact pyrometers and imagers, heat flux indicators, and the performance parameters of noncontact devices.
Key facts
- Contact devices: thermocouples (Seebeck effect, two dissimilar metals), RTDs (resistance of platinum rises with temperature), thermistors, and temperature-indicating crayons, paints, labels and liquid crystals.
- Noncontact devices: spot radiometers (pyrometers), ratio (two-color) pyrometers, line scanners and imaging cameras.
- Wavebands: short/mid-wave about 3 to 5 µm and long-wave about 8 to 14 µm, matching atmospheric windows.
- Performance parameters: IFOV (spatial resolution), measurement spot (often 3 × IFOV), NETD (thermal sensitivity), accuracy, range, frame rate and spectral band.
- Ordinary glass is opaque in the long-wave band; infrared windows use materials such as calcium fluoride, germanium, zinc selenide or IR-transparent polymers.
- Ratio pyrometers tolerate partial obscuration and graybody emissivity changes but err on selective emitters.
- Heat flux sensors measure heat flow per unit area directly, often with a thermopile across a thin layer.
Flashcards
Exam tip: For every instrument, know what it actually senses: voltage, resistance, radiance in one band, or a ratio of two bands. Its error sources follow from that.
3. Thermal and Infrared Techniques
Contact and noncontact techniques, line scanners and imaging, and the investigation types ASNT lists: exothermic or endothermic, friction, fluid flow, thermal resistance and thermal capacitance.
Key facts
- Passive thermography uses heat already present (process, electrical load, sun); active thermography applies heat (flash, lamps, induction, ultrasound) to the test object.
- Pulsed (transient) thermography: deeper defects appear later, with time roughly proportional to depth squared over diffusivity, and with less contrast.
- Lock-in thermography uses modulated heating and phase images, which are less sensitive to emissivity variation.
- Exothermic or endothermic: chemical reactions, curing, electrical I²R heating. Friction: bearings, couplings, misalignment, belts.
- Fluid flow: blocked tubes, valve leak-by, steam traps, refractory loss, air leakage in buildings.
- Thermal resistance (steady state): missing insulation, delaminated linings, refractory damage; needs a steady heat flow.
- Thermal capacitance (transient): tank levels, roof moisture, water ingress in composites, seen as lagging surfaces during heating or cooling.
- Line scanners suit moving targets such as rotary kilns, strip steel and conveyor processes.
Flashcards
Exam tip: Classify each scenario by investigation type first. The correct timing and conditions follow: steady state for resistance, transient for capacitance.
Test yourself on these topics
Take the free 15-question IR Thermography Level III test, then save your results to unlock your Readiness Score and the mistakes bank.
4. Interpretation and Evaluation
Turning thermal images and readings into findings: emissivity, reflections, transmission, spot size, load and environmental effects, and severity grading.
Key facts
- Accurate radiometric temperature needs correct emissivity, reflected apparent temperature, distance, atmospheric temperature and humidity, and any window transmission.
- Low-emissivity surfaces (bare, polished metal) read low and reflect surroundings; measure painted or taped spots, or use comparative methods.
Flashcards
Exam tip: Before grading a hot spot, ask: is the emissivity right, is the spot big enough, what is the load, and what are the wind and sun doing?
5. Procedures and Standards
Writing and following thermal/infrared procedures and the standards that support them: ASTM equipment and practice standards, building and electrical inspection standards, and reporting.
Key facts
- ASTM E1934: guide for examining electrical and mechanical equipment with infrared thermography.
- ASTM E1862 (reflected temperature) and E1933 (emissivity) give test methods for measuring and compensating radiometric errors.
Flashcards
Exam tip: Match each standard number to its job: E1862 reflected temperature, E1933 emissivity, E1934 equipment inspections, C1060 walls, C1153 roofs.
6. Safety and Health
Safety responsibility and authority, and safety for personnel, for the client and facilities, and for testing equipment.
Key facts
- Safety responsibility: the employer and the client's site rules set authority; the Level III makes sure procedures include hazard controls.
- Electrical work: removing covers from energized equipment needs an arc flash and shock risk assessment (NFPA 70E in the US), approach boundaries and PPE.
Flashcards
Exam tip: Safety answers name a control that removes or limits the hazard, not just a reminder to be careful.
How to pass
- 90 questions in 2 hours is 80 seconds each. Keep the Stefan-Boltzmann, Wien, Fourier and spot-size arithmetic short.
- Always convert to kelvin before using T⁴ or Wien's law. A Celsius value in either formula gives a wrong but tempting answer.
- For every measurement question, check emissivity, reflected apparent temperature, transmission (windows, atmosphere) and spot size before trusting a number.
- ASNT's techniques list is organized by investigation type: exothermic or endothermic, friction, fluid flow, thermal resistance and thermal capacitance. Know an application for each.
Frequently asked questions
How long should I study for the IR Thermography Level III exam?
Most working candidates need 4 to 8 weeks at 45 to 60 minutes a day. Book your exam once your Readiness Score has stayed at 80 or higher for about a week.
Can I take the IR Thermography Level III exam online?
No. ASNT NDT Level III exams are taken in person, on a computer, at Pearson VUE test centers or ASNT Authorized Exam Centers. Format: closed book, computer-based, with an on-screen calculator. no practical exam. you must also pass the ndt basic exam to be certified. Check ASNT's current exam information for the rules.
What score do I need to pass the IR Thermography Level III exam?
Not published per exam. Aim for 80% or higher in practice (ASNT says its criterion-referenced cut scores are typically 70% to 80%). The exam has 90 multiple-choice questions and a time limit of 2 hours.
What are the most tested topics?
The outline covers principles and theory of heat transfer, equipment and materials, thermal and infrared techniques, interpretation and evaluation, procedures and standards, safety and health. Use the free practice test to see which ones you need most.
The premium IR Thermography Level III study path
Premium IR Thermography Level III prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.
Your step-by-step study path
- 1Principles and Theory of Heat Transfer10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25Notes free with an account
- 2Equipment and Materials10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25Premium
- 3Thermal and Infrared Techniques10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25Premium
- 4Interpretation and Evaluation10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25Premium
- 5Procedures and Standards10 key notes, 130 flashcards, then 500 practice questions in 20 sets of 25Premium
- 6Safety and Health10 key notes, 130 flashcards, then 500 practice questions in 20 sets of 25Premium
- Final step: 6 full mock exams90 questions each, timed like test day. Pass them, then book your exam.Premium
Get every note, flashcard and question
Premium Monthly
- One ASNT Level III exam of your choice: Basic, UT, RT or MT
- 3,000 practice questions + 6 full mock exams per exam
- 800 flashcards + 60 key notes per exam, by topic, plus mind maps
- Spaced repetition + mistakes bank
- Readiness Score & detailed reports
- Video lessons as they release
- Content updates during your access
- 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
- Pass Guarantee: complete the prep, pass or 100% back
Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.
Premium Yearly
- One ASNT Level III exam of your choice: Basic, UT, RT or MT
- 3,000 practice questions + 6 full mock exams per exam
- 800 flashcards + 60 key notes per exam, by topic, plus mind maps
- Spaced repetition + mistakes bank
- Readiness Score & detailed reports
- Video lessons as they release
- Content updates during your access
- 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
- Pass Guarantee: complete the prep, pass or 100% back
Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.