ASNT's third-party radiation safety certification for industrial radiographers working with sealed sources, meeting 10 CFR Part 34 and the Suggested State Regulations. It requires 40 hours of radiation safety training and 200 hours (29 days) of RAM experience, and is renewed every five years. This prep covers only the 100-item written exam, not the practical exam your employer conducts.

Watch the free 4:17 video lesson: the key ASNT IRRSP RAM concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free ASNT IRRSP RAM study dashboard: flashcards, notes and your Readiness Score, no signup →

About the ASNT IRRSP RAM exam

ASNT's third-party radiation safety certification for industrial radiographers working with sealed sources, meeting 10 CFR Part 34 and the Suggested State Regulations. It requires 40 hours of radiation safety training and 200 hours (29 days) of RAM experience, and is renewed every five years. This prep covers only the 100-item written exam, not the practical exam your employer conducts.

What's on the exam

ASNT IRRSP RAM
Fundamentals of Radiation Safety
7 key facts
Exposure and Effects
7 key facts
Controlling Exposure
7 key facts
Radiation Detection
7 key facts
Radiographic Equipment
8 key facts
Regulations
7 key facts
Operating and Emergency Procedures
7 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the ASNT IRRSP RAM exam

  • 100 items in 3 hours is 108 seconds each, which leaves time for inverse-square and half-value-layer calculations. Save a few minutes to recheck units.
  • Memorize the Part 34 numbers as pairs: what is checked and how often, such as survey meters at 6 months, leak tests at 6 months and the inventory quarterly.
  • Know which rule is federal and which is your state's. ASNT draws on 10 CFR and the Suggested State Regulations, and Agreement State rules can differ in detail.
  • If you fail more than three times in one year, ASNT requires 20 hours of additional radiation safety training and a six-month wait before you can reapply.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the NDT Level III Formula Sheet.

Take the test first

What's in the premium ASNT IRRSP RAM prep

Premium ASNT IRRSP RAM prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 100 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 7 topics

Your step-by-step study path

  1. 1
    Fundamentals of Radiation Safety9 key notes, 115 flashcards, then 450 practice questions in 18 sets of 25
    Notes free with an account
  2. 2
    Exposure and Effects9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  3. 3
    Controlling Exposure9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  4. 4
    Radiation Detection9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  5. 5
    Radiographic Equipment8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  6. 6
    Regulations8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  7. 7
    Operating and Emergency Procedures8 key notes, 110 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  8. Final step: 6 full mock exams100 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete ASNT IRRSP RAM study notes for “Fundamentals of Radiation Safety”

Our first full set of comprehensive notes, about 12 minutes of reading: Types of radiation · Where gamma radiation comes from · Units · Interaction with matter · Half-life and source output, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. A sealed source's paperwork lists its activity as 3.7 TBq. About how many curies is this?
Answer: 100 Ci. One curie is 3.7 × 10¹⁰ Bq, and 3.7 TBq is 3.7 × 10¹² Bq, so the source is 100 Ci. The usual slip is losing a factor of 10 or 100 when converting prefixes. Practice converting among Bq, kBq, GBq and TBq, since source documents may use either unit.
2. A dose report shows 30 mSv total effective dose equivalent so far this year. How many more rem can this adult radiation worker receive before reaching the 5 rem limit?
Answer: 2 rem. Since 10 mSv equals 1 rem, 30 mSv is 3 rem, leaving 5 - 3 = 2 rem under 10 CFR 20.1201. Treating 30 mSv as 0.3 rem gives the tempting 4.7 rem. Company administrative limits are usually lower than the regulatory limit.
3. Which of these is a deterministic (tissue reaction) effect of a high radiation dose?
Answer: Skin reddening after an acute exposure. Deterministic effects appear above a threshold, and their severity rises with dose, as with skin reddening or burns. Cancer, leukemia and heritable effects are stochastic: the probability rises with dose, but severity doesn't. Dose limits are set to prevent deterministic effects and to limit stochastic risk.
4. An uncollimated 30 Ci Ir-192 source gives 5.2 R/h per curie at 1 ft. About how far away is the 2 mR/h boundary, ignoring other shielding?
Answer: 280 ft. At 1 ft the rate is 30 × 5.2 = 156 R/h, or 156,000 mR/h. Distance is the square root of 156,000 / 2 = 78,000, about 279 ft. Skipping the square root, or forgetting that R and mR differ by 1,000, produces wildly different answers.
5. A 50 Ci Ir-192 source gives 5.2 R/h per curie at 1 ft and a collimator provides 4 half-value layers toward a worker. About how far from the source is the 100 mR/h line in that direction?
Answer: 13 ft. At 1 ft the unshielded rate is 260 R/h, and 4 half-value layers divide that by 16 to give 16.25 R/h, or 16,250 mR/h. Distance is the square root of 16,250 / 100 = 162.5, about 13 ft. Without the collimator the distance would be 51 ft, so don't drop the shielding step.
6. During each shot, a radiographer stands where the rate is 200 mR/h for a total of 20 seconds while the source is cranked out and back. What dose comes from 30 shots?
Answer: 33 mrem. Each shot gives 200 × (20/3600) = 1.11 mrem, and 30 shots gives about 33 mrem. Forgetting to convert seconds to hours is the common error. Short crank-out times matter because the same dose rate adds up across every shot of the day.
7. A survey meter passes its check-source test today, but its calibration sticker is 7 months old. Under 10 CFR 34.25, may it be used for required surveys?
Answer: No, since calibration intervals may not exceed 6 months. Survey instruments must be calibrated at intervals not exceeding 6 months and after servicing other than battery changes. A check source confirms operability only, so it can't substitute for calibration. The daily check is a separate requirement under 34.31.
8. A radiographer's pocket dosimeter is off-scale and a real exposure can't be ruled out. What does 10 CFR 34.47 require?
Answer: Stop work and send the badge for processing within 24 hours. The badge must go for processing within 24 hours, and the worker can't resume work with licensed material until the RSO or designee has determined the dose. Recharging erases evidence and returns the worker to duty too soon. Record the result in the personnel monitoring records.
9. A storage container with the sealed source shielded reads 150 mrem/h at its surface and 12 mrem/h at 1 m. What is the correct conclusion under 10 CFR 34.21?
Answer: It fails, since the limit at 1 m is 10 mrem/h. Part 34 limits storage containers and source changers to 200 mrem/h at any exterior surface and also to 10 mrem/h at 1 m. The surface reading is fine, but 12 mrem/h at 1 m exceeds the limit. Both conditions must be met.
10. A leak test wipe from an Ir-192 source shows 0.008 µCi of removable activity. What is required under 10 CFR 34.27?
Answer: Withdraw it immediately and file a report within 5 days. A result of 0.005 µCi (185 Bq) or more is evidence of leakage, so the equipment comes out of use at once and is decontaminated, repaired or disposed of. The report is due within 5 days of the test. The 6-month interval is the routine testing period, and it doesn't apply once a leak is found.
11. A radiographer arrives at a temporary jobsite, and the assistant has called in sick. May the radiographer perform the shots alone under 10 CFR 34.41?
Answer: No, since at least two qualified people must be present. Radiography away from a permanent installation needs at least one additional qualified radiographer or assistant present, able to give immediate help and prevent unauthorized entry. A client's untrained staff don't meet that requirement. Posting and alarm ratemeters are required as well, not instead.
12. A package measures 30 mrem/h at its surface and 0.6 mrem/h at 1 m (transport index 0.6). Which label does 49 CFR 172.403 require?
Answer: Radioactive Yellow-II. Yellow-II covers a surface level above 0.5 mrem/h and up to 50 mrem/h, with a transport index above 0 and up to 1. This package fits. White-I needs a surface level of 0.5 mrem/h or less, and Yellow-III applies above 50 mrem/h or above a transport index of 1.
13. A radiographer has done no industrial radiography for 8 months since the last job-performance inspection. What is required before returning to radiography under 10 CFR 34.43(e)?
Answer: Demonstrated knowledge through a practical examination. After more than 6 months without participating since the last inspection, the radiographer must re-demonstrate knowledge of equipment use by a practical examination before the next operation. The annual refresher is a separate requirement. Certification itself stays valid, so a new written exam isn't needed.
14. During a field shot, the source won't retract and the crank is jammed. What is the correct first response?
Answer: Hold the boundary, keep surveillance and call the RSO. Keep people out, maintain surveillance of the boundary and notify the RSO, who manages recovery under the emergency procedures. Only authorized, trained people may recover a source, and handling a source can cause severe local injury. The 30-day report under 34.101 is required later, not instead of the immediate response.
15. A radiographer will leave a locked exposure device out of sight for a short break at a temporary jobsite. What does Part 34 require?
Answer: Lock it, remove the key and physically secure it. Under 34.23, a device not under direct surveillance must be locked with the key removed, and 34.35 requires locked devices to be physically secured against tampering or removal. A posted boundary doesn't prevent theft. Each return to the shielded position is also followed by securing the source.

Get the full ASNT IRRSP RAM prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a retake fee, for the certification that lets you approve procedures and certify technicians
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

ASNT IRRSP RAM exam FAQ

How many questions are on the ASNT IRRSP RAM exam?

100 multiple-choice items on the written exam. A separate practical exam is conducted by the employer, with the completed form submitted within six months of the computer-based exam, with a time limit of 3 hours. Format: computer-based multiple choice with an on-screen scientific calculator supplied by asnt. not published by asnt whether references may be used; confirm with asnt. this prep covers only the written exam, not the employer-conducted practical or visual acuity exams.

What is the passing score for ASNT IRRSP RAM?

Minimum 70% on the written exam (ASNT-CP-IRRSP, 2020 Edition), plus successful completion of the employer-conducted practical exam.

How much does the ASNT IRRSP RAM exam cost?

US$300 for ASNT members, US$325 for nonmembers. Retake US$260 / US$285. ASNT fees differ for members and nonmembers and can change, so confirm on the ASNT certification website before you apply.

Which languages is the ASNT IRRSP RAM exam offered in?

English only (an online NDT terminology dictionary covers Korean, Mandarin, Spanish, UK English and Arabic).

Where do I take the ASNT IRRSP RAM exam?

Pearson VUE test centers and ASNT Authorized Exam Centers (in person, computer-based). The practical exam is conducted by the employer.

Is this ASNT IRRSP RAM practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full ASNT IRRSP RAM prep is Premium at $147 a month for this exam.

What's in the premium ASNT IRRSP RAM prep?

3,000 practice questions organized topic by topic (Fundamentals of Radiation Safety: 450; Exposure and Effects: 425; Controlling Exposure: 425; Radiation Detection: 425; Radiographic Equipment: 425; Regulations: 425; Operating and Emergency Procedures: 425), 6 full-length timed mock exams of 100 questions, 800 flashcards and 60 comprehensive key notes split across all 7 topics, plus a mistakes bank and the Readiness Score.