Try the full study dashboard free, no signup: practice, flashcards and your Exam Readiness Score. Open it →
Home / Practice tests / LT Level III
ASNT · Last updated November 2026

ASNT NDT Level III Leak Testing (LT): free practice test

The ASNT Level III leak testing method exam: 135 questions in 4 hours on principles and gas flow, equipment and materials, techniques and calibration, interpretation and evaluation, procedures and specifications, and safety. It covers bubble, pressure change, halogen and helium mass spectrometer testing. LT is not one of ASNT's ANAB-accredited Level III methods.

Watch the free 4:19 video lesson: the key LT Level III concepts →

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free LT Level III study dashboard: flashcards, notes and your Readiness Score, no signup →

About the LT Level III exam

The ASNT Level III leak testing method exam: 135 questions in 4 hours on principles and gas flow, equipment and materials, techniques and calibration, interpretation and evaluation, procedures and specifications, and safety. It covers bubble, pressure change, halogen and helium mass spectrometer testing. LT is not one of ASNT's ANAB-accredited Level III methods.

What's on the exam

LT Level III
Principles of Leak Testing and Gas Flow
7 key facts
Leak Testing Equipment and Materials
7 key facts
Leak Testing Techniques and Calibration
8 key facts
Interpretation and Evaluation
7 key facts
Leak Testing Procedures and Specifications
6 key facts
Safety and Health
6 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the LT Level III exam

  • 135 questions in 4 hours is about 106 seconds each. That leaves time for the calculations: leak rate from pressure change, temperature correction, calibration ratios and unit conversions.
  • Always work in absolute pressure and absolute temperature. Most wrong answers in pressure change problems come from using gauge pressure or degrees Celsius.
  • Know which flow regime you are in. Viscous flow scales with P1² minus P2² and with viscosity; molecular flow scales with the pressure difference and 1 over the square root of molecular mass.
  • For each technique, know its sensitivity range, its tracer, its calibration (calibrated leak, response time, scanning rate) and its typical false indications.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the NDT Level III Formula Sheet.

Take the test first

What's in the premium LT Level III prep

Premium LT Level III prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 135 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 6 topics

Your step-by-step study path

  1. 1
    Principles of Leak Testing and Gas Flow10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Notes free with an account
  2. 2
    Leak Testing Equipment and Materials10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  3. 3
    Leak Testing Techniques and Calibration10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  4. 4
    Interpretation and Evaluation10 key notes, 135 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  5. 5
    Leak Testing Procedures and Specifications10 key notes, 130 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  6. 6
    Safety and Health10 key notes, 130 flashcards, then 500 practice questions in 20 sets of 25
    Premium
  7. Final step: 6 full mock exams135 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete LT Level III study notes for “Principles of Leak Testing and Gas Flow”

Our first full set of comprehensive notes, about 15 minutes of reading: Leaks, leakage and leak rate · Gas laws you need · Flow regimes · Choosing leak testing as the method, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. A leak in viscous (laminar) flow gives leak rate Q when the part is at 2 atm absolute and the outside is at 1 atm. About what leak rate is expected at 5 atm absolute inside?
Answer: 8Q. In laminar viscous flow the leak rate is proportional to P1² minus P2²: (25 − 1) ÷ (4 − 1) = 8. Scaling by the pressure difference alone (4 ÷ 1) or the inside pressure alone (5 ÷ 2) is the molecular-flow or simple-ratio mistake.
2. A very small leak is in molecular flow. At the same pressures and temperature, how does its helium leak rate compare with its air leak rate?
Answer: About 2.7 times higher. In molecular flow the leak rate varies with 1 over the square root of molecular mass: √(29 ÷ 4) ≈ 2.7, so helium flows faster. Using the mass ratio without the square root gives 7, a common error.
3. A newly fabricated vessel is to receive a helium mass spectrometer test with a tight acceptance limit. Why is a bubble or pressure test usually done first?
Answer: A gross leak would flood the detector and area with helium and mask small leaks. Large leaks saturate the detector, raise the helium background and contaminate the work area, so small leaks are missed. Good method selection runs coarse tests first, then the sensitive one. Helium passes large leaks easily; that is the problem.
4. In a counterflow helium leak detector, helium reaches the analyzer by diffusing backward through the turbomolecular pump. What is the main advantage?
Answer: Testing can start at higher test-port pressure while heavier gases are held back. A turbo pump has a low compression ratio for light gases and a high one for heavy gases, so helium diffuses back to the analyzer while water vapor and nitrogen are kept out. The analyzer stays at high vacuum while the test object is still at a higher pressure. A backing pump is still needed.
5. In a heated-anode halogen diode detector, what physical change produces the leak signal?
Answer: Positive ion emission from the heated platinum element rises when halogens are present. The heated platinum anode emits positive ions, and the emission rises sharply when halogen-bearing tracer gas reaches it. Thermal conductivity detectors and mass spectrometers work differently. High halogen concentrations can poison the element and reduce sensitivity.
6. In a helium tracer probe test, a 600 L system is pumped by the detector with an effective helium pumping speed of 20 L/s. What is the response time (time to about 63% of final signal)?
Answer: 30 s. Response time is the time constant V ÷ S = 600 ÷ 20 = 30 s. About three time constants are needed for 95% of the final signal, so the probe dwell and the procedure must allow for it. Dividing the wrong way or ignoring volume gives the other values.
7. Under ASME Section V Article 10, unless the referencing code says otherwise, what partial vacuum is required for the vacuum box bubble technique?
Answer: At least 2 psi (14 kPa) below atmospheric. Article 10 requires a partial vacuum of at least 2 psi (14 kPa) below atmospheric pressure, or the value the referencing code requires, with a gauge to confirm it. Each box placement must overlap the last so no length of weld is missed.
8. An assembly filled with 20% helium in air gives a detector probe reading of 3 × 10⁻⁶ std cm³/s of helium at a leak. What is the total gas leak rate?
Answer: 1.5E-05 std cm³/s. The detector measures only helium, so divide by the tracer fraction: 3 × 10⁻⁶ ÷ 0.20 = 1.5 × 10⁻⁵ std cm³/s. Multiplying by the fraction instead gives 6 × 10⁻⁷. If the calibrated leak was set up for pure helium, the same correction applies to the acceptance check.
9. A sealed vessel is at 200.0 kPa absolute and 20 °C. Six hours later the gauge reads 196.0 kPa absolute and the gas is at 15 °C. After temperature correction, how much pressure was lost to leakage?
Answer: About 0.6 kPa. Correct to the starting temperature in kelvin: 196.0 × 293.15 ÷ 288.15 = 199.4 kPa, so the leakage loss is about 0.6 kPa. Ignoring temperature gives 4.0 kPa; applying the ratio upside down gives about 7.4 kPa. Cooling alone would only drop the pressure to 196.6 kPa.
10. A helium detector reads 50 divisions with a 4 × 10⁻⁸ std cm³/s calibrated leak open and 10 divisions with it closed. A leak then reads 30 divisions against the same 10-division background. What is the leak rate?
Answer: 2 × 10⁻⁸ std cm³/s. Subtract background from both readings: the calibrated leak gives 40 divisions, so 1 division = 1 × 10⁻⁹. The leak gives 20 divisions, or 2 × 10⁻⁸ std cm³/s. Forgetting background on one or both readings gives the other values.
11. In a helium hood test of an assembly sealed with elastomer O-rings, the signal rises slowly and steadily over several minutes with no sharp response when helium is applied. What is the most likely cause?
Answer: Helium permeating through the elastomer seals. Permeation through elastomers starts after a delay and climbs gradually, unlike a real leak, which responds within the system response time. A gross leak gives a fast, large signal. The analyzer is tuned to mass 4, so hydrogen (mass 2) is not read as helium.
12. An acceptance criterion is written as 1 × 10⁻⁶ Pa·m³/s. Which value is equivalent?
Answer: 1.0E-05 mbar·L/s. 1 Pa·m³/s = 10 mbar·L/s, because 1 Pa = 0.01 mbar and 1 m³ = 1000 L. So 1 × 10⁻⁶ Pa·m³/s = 1 × 10⁻⁵ mbar·L/s, which is also about 1 × 10⁻⁵ std cm³/s.
13. When the Level III writes a leak testing procedure for work under a construction code, which item comes from the referencing code or design specification rather than from the Level III?
Answer: The acceptance criterion (allowable leak rate). ASME Section V Article 10 sets how to test; the referencing code section or design specification sets the acceptance standard. The procedure must state the criterion but the Level III does not choose it. Scanning rate, calibration and sequence are procedure details the Level III sets and demonstrates.
14. A pressure change test will be run at 30 psig. Under ASME Section V Article 10, which dial gauge range is acceptable?
Answer: 0 to 60 psig. Article 10 asks for dial gauges with a range of about twice the test pressure and never less than 1.5 nor more than 4 times it: 45 to 120 psig here. 0 to 60 psig fits. 0 to 40 is under 1.5 times and 0 to 160 is over 4 times.
15. A technician must enter a vessel that was just leak tested with nitrogen. What must be confirmed before entry?
Answer: Oxygen in the atmosphere is at least 19.5% by volume. Nitrogen and helium are asphyxiants: they displace oxygen without warning. OSHA treats air below 19.5% oxygen as oxygen-deficient, so test the atmosphere and follow confined space entry rules. Nitrogen is not flammable, so a flammable limit check misses the hazard.

Get the full LT Level III prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a retake fee, for the certification that lets you approve procedures and certify technicians
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

LT Level III exam FAQ

How many questions are on the LT Level III exam?

135 multiple-choice questions, with a time limit of 4 hours. Format: closed book, computer-based, with an on-screen calculator. no practical exam. you must also pass the ndt basic exam to be certified.

What is the passing score for LT Level III?

Not published per exam. Aim for 80% or higher in practice (ASNT says its criterion-referenced cut scores are typically 70% to 80%).

How much does the LT Level III exam cost?

US$545 for ASNT members, US$625 for nonmembers (retake US$475 / US$555). ASNT fees differ for members and nonmembers and can change, so confirm on the ASNT certification website before you apply.

Which languages is the LT Level III exam offered in?

English (an online NDT terminology translation dictionary is available).

Where do I take the LT Level III exam?

Pearson VUE test centers and ASNT Authorized Exam Centers (in person, computer-based).

Is this LT Level III practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full LT Level III prep is Premium at $147 a month for this exam.

What's in the premium LT Level III prep?

3,000 practice questions organized topic by topic (Principles of Leak Testing and Gas Flow: 500; Leak Testing Equipment and Materials: 500; Leak Testing Techniques and Calibration: 500; Interpretation and Evaluation: 500; Leak Testing Procedures and Specifications: 500; Safety and Health: 500), 6 full-length timed mock exams of 135 questions, 800 flashcards and 60 comprehensive key notes split across all 6 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in October 2026. ASNT changes formats and fees, so confirm with ASNT Certification Services LLC (American Society for Nondestructive Testing) before you book. NDTLevel3Exam is not affiliated with ASNT or Pearson VUE.

Start the free test