Try the full study dashboard free, no signup: practice, flashcards and your Exam Readiness Score. Open it →
Home / Study guides / ASNT NDT Level II MT
Study guide · Last updated November 2026

ASNT NDT Level II MT Exam Study Guide (2026)

Everything the ASNT NDT Level II, Magnetic Particle Testing (MT) tests, topic by topic: what each section covers, the facts that come up most, and how to study it. Pair it with the free 15-question practice test.

The exam at a glance

QuestionsTwo multiple-choice exams: General 50 items and Specific 40 items (general industry or pressure equipment sector)
TimeGeneral 2 hours; Specific 2 hours (4 hours in total)
Passing scoreNot published by ASNT for this exam. ASNT says its criterion-referenced cut scores are typically 70% to 80%. Both the General and the Specific exam must be passed, so aim for 80% or higher on each in practice
FormatComputer-based multiple choice with an on-screen calculator. ASNT does not publish whether any reference is supplied during these exams; confirm with ASNT. This prep covers only the written General and Specific exams, not the employer's visual acuity, practical or job-specific exams
Certifying bodyASNT Certification Services LLC (American Society for Nondestructive Testing)
Test providerPearson VUE test centers and ASNT Authorized Exam Centers (in person, computer-based, no walk-ins)

Mind map: the whole exam on one screen

ASNT NDT Level II MT
MT Principles and Theory
Field from a central conductor through a ringProperty that allows the residual methodCurrent type for near-surface discontinuities with wet particlesBest angle between flux and discontinuity
Use and Care of MT Equipment and Accessories
Minimum AC yoke lift, ASME V Art 7Visible wet bath concentration rangeMinimum UV-A at the surface, ASME V Art 7Minimum DC yoke lift, ASME V Art 7
MT Techniques and Demagnetization
High fill-factor coil formulaWhy prods are banned on some high-strength steelsHow to demagnetize a part held in a circular fieldLow fill-factor coil formula, part against the coil wall
Interpreting, Evaluating and Documenting Results
6 key facts
Codes, Standards, Specifications and Procedures
6 key facts
Specific Exam: General Industry
6 key facts
Specific Exam: Pressure Equipment
6 key facts
Free with an account

Read the complete ASNT NDT Level II MT study notes for “MT Principles and Theory”

Our first full set of comprehensive notes, about 15 minutes of reading: How MT works · Field direction · Magnetic properties · Current and particles, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

1. MT Principles and Theory

First domain of the MT General outline for exams after 15 December 2026: select field type for the part form, select magnetizing current and particle type, and guide Level I and trainee personnel on theory. It absorbs the earlier topics of principles, flux fields, effects of discontinuities and magnetization by electric current. ASNT publishes no percentage weights.

Key facts

  • MT works on ferromagnetic materials only; a discontinuity across the flux lines creates a leakage field that holds particles.
  • Best detection is with the flux at 90° to the discontinuity; detection falls off below about 45°.
  • Current through a part (head shot, prods, central conductor) gives a circular field; a coil or yoke gives a longitudinal field. Right-hand rule: thumb along current, fingers show field direction.
  • Permeability is ease of magnetizing; reluctance is resistance to flux; retentivity is the residual field held; coercive force is the reverse force needed to remove it.
  • AC concentrates the field at the surface (skin effect) and gives particle mobility; rectified DC penetrates deeper for near-surface discontinuities.
  • Continuous method: apply particles while current flows. Residual method: apply after, only on high-retentivity materials.
  • Iron loses ferromagnetism above the Curie point, about 770°C (1,418°F).

Flashcards

Field from a central conductor through a ringCircular, running around the ring.
Property that allows the residual methodHigh retentivity.
Current type for near-surface discontinuities with wet particlesFull-wave rectified DC.
Best angle between flux and discontinuity90°.

Exam tip: For any setup question, draw the current and the field. The discontinuity it finds is the one lying across the field.

2. Use and Care of MT Equipment and Accessories

Second domain of the post-15 December 2026 outline: verify equipment and tool calibration, set up equipment, perform daily standardizations (10 lb and 40 lb lift tests, Ketos ring, QQIs), verify particle concentration and contamination, check UV-A and white light, use field indicators and keep equipment and consumables in order.

Key facts

  • Yoke lift (ASME Section V Article 7): AC at least 10 lb, DC or permanent magnet at least 40 lb, at the maximum pole spacing used.
  • Wet bath settling test: fluorescent 0.1 to 0.4 mL per 100 mL; visible 1.2 to 2.4 mL per 100 mL. Too high masks indications; too low misses them.
  • UV-A at the surface: at least 1,000 µW/cm² under Article 7; ambient white light in the booth no more than 2 fc (20 lx); visible-particle exams need at least 100 fc (1,000 lx).
  • Ketos (Betz) ring with a central conductor checks overall system performance; the number of holes shown rises with current.
  • QQIs (shims) and pie gauges show field direction and adequacy; Hall-effect gaussmeters measure the tangential field, often 30 to 60 G under Article 7.
  • Ammeters on magnetizing equipment are calibrated at least yearly under Article 7.
  • A cracked UV-A filter takes the lamp out of service.

Flashcards

Minimum AC yoke lift, ASME V Art 710 lb at the maximum pole spacing used.
Visible wet bath concentration range1.2 to 2.4 mL per 100 mL.
Minimum UV-A at the surface, ASME V Art 71,000 µW/cm².
Minimum DC yoke lift, ASME V Art 740 lb.

Exam tip: Know which check belongs to which equipment: lift tests for yokes, ammeter calibration for bench and mobile units, Ketos ring for wet horizontal units.

3. MT Techniques and Demagnetization

Third domain of the post-15 December 2026 outline: select technique; apply direct contact, central conductor, prod, coil and yoke techniques; examine castings, forgings and welds; apply and verify demagnetization. It covers the earlier topics of selecting the method of magnetization and demagnetization procedures.

Key facts

  • Coil formulas (Article 7, L/D from 2 to 15): high fill factor NI = 35,000 ÷ (L/D + 2); low fill factor, part against the coil wall, NI = 45,000 ÷ (L/D).
  • Direct contact (head shot): 300 to 800 A per inch of diameter under Article 7.
  • Prods: 3 to 8 in spacing; 90 to 110 A per inch of spacing under 3/4 in thick, 100 to 125 A per inch at 3/4 in and over.
  • Prods can arc and leave hard spots; many specifications ban them on high-strength or quenched and tempered steels.
  • Examine each area twice with fields about 90° apart.
  • Demagnetize longitudinally after a circular field: a contained circular field is converted to a longitudinal one, then removed.
  • AC demagnetization: withdraw the part well clear of the coil with current on, ideally with the long axis east-west.

Flashcards

High fill-factor coil formulaNI = 35,000 ÷ (L/D + 2).
Why prods are banned on some high-strength steelsArcing can cause hard spots and cracks.
How to demagnetize a part held in a circular fieldConvert to a longitudinal field, then demagnetize it.
Low fill-factor coil formula, part against the coil wallNI = 45,000 ÷ (L/D).

Exam tip: Write the coil formula with units before plugging in numbers, and remember to divide ampere-turns by the number of turns.

Test yourself on these topics

Take the free 15-question ASNT NDT Level II MT test, then save your results to unlock your Readiness Score and the mistakes bank.

Start the free test

4. Interpreting, Evaluating and Documenting Results

Fourth domain of the post-15 December 2026 outline: characterize indications (relevant, nonrelevant, type), identify false indications, size them, record test data and report findings with essential variables. It covers the earlier topics of types of discontinuities and evaluation techniques.

Key facts

  • Relevant indications come from discontinuities; nonrelevant ones from real leakage fields without a flaw (section changes, permeability changes, magnetic writing); false ones from poor cleaning or handling.
  • Cracks give sharp, tight, well-defined lines; subsurface discontinuities give broader, fuzzier indications.
4 more key facts, 9 key notes, 115 flashcards and 425 practice questions for this topic are in premium.

Flashcards

Appearance of a quench crackSharp, jagged, often branching, at corners or section changes.

Exam tip: To classify an indication, ask: does it come back after cleaning and reprocessing, and does it match a geometry or material change?

5. Codes, Standards, Specifications and Procedures

Fifth domain of the post-15 December 2026 outline: apply safety protocols, develop MT work instructions, select and apply the correct procedure (equations, formulas, tests) and determine acceptance or rejection. It covers the earlier quality control of equipment and processes topic.

Key facts

  • ASME Section VIII Division 1 Appendix 6: only indications over 1/16 in are relevant; linear means length at least 3 times width.
  • Appendix 6 rejects relevant linear indications, rounded indications over 3/16 in, and four or more rounded indications in a line separated by 1/16 in or less edge to edge.
4 more key facts, 8 key notes, 115 flashcards and 425 practice questions for this topic are in premium.

Flashcards

Four or more rounded indications in a line, 1/16 in or less apart (Appendix 6)Reject.

Exam tip: Learn Appendix 6 as three rejection rules. Most acceptance questions are a matter of checking each rule in turn.

6. Specific Exam: General Industry

One of two 40-item, 2-hour Specific exams covering codes, applications and techniques for the general industry sector. ASNT does not name the documents; ASTM E1444 and E709 are the usual references.

Key facts

  • ASTM E1444: residual field after demagnetization no more than 3 G (0.3 mT) unless otherwise specified.
  • E1444 requires daily system performance checks, such as a Ketos ring or a known-defect part, and periodic bath, light and equipment checks.
4 more key facts, 8 key notes, 115 flashcards and 425 practice questions for this topic are in premium.

Flashcards

Residual field limit, ASTM E1444, unless otherwise specifiedNo more than 3 G (0.3 mT).

Exam tip: General industry questions often involve aerospace parts: demagnetization limits, daily system checks and documentation are frequent themes.

7. Specific Exam: Pressure Equipment

The other 40-item, 2-hour Specific exam, covering codes, applications and techniques for the pressure equipment sector. ASNT does not name the documents; ASME Section V Article 7 and Section VIII Division 1 Appendix 6 are the usual references.

Key facts

  • Article 7 requires a written procedure with essential variables such as technique, current type, particle type and surface preparation.
  • Ammeters are calibrated at least once a year or after major repair; yokes are lift-checked at least once a year and after damage.
4 more key facts, 8 key notes, 110 flashcards and 425 practice questions for this topic are in premium.

Flashcards

Events besides the yearly interval that trigger ammeter recalibrationMajor electrical repair, periodic overhaul or damage.

Exam tip: Section V tells you how to examine; the construction code tells you what to accept. Keep the two apart.

How to pass

  • Check your exam date against 15 December 2026. Earlier General exams use the ten-topic outline (flux fields, magnetization, demagnetization, discontinuities); later ones use five job-task domains that add daily standardizations such as lift tests, Ketos rings and QQIs.
  • ASNT publishes no cut score for this exam. The 70% per exam and 80% composite figures often quoted come from employer programs under SNT-TC-1A, so treat 80% on each exam as your practice target.
  • ASNT's public page does not name the codes behind the Specific exams. ASME Section V Article 7 and Section VIII Appendix 6 are the usual references for pressure equipment, and ASTM E1444 and E709 for general industry, so learn their numbers.
  • A passed General result stays valid for 5 years but a passed Specific result only for 2 years, so book them close together. After a failure you reapply and wait 30 days.

Frequently asked questions

How long should I study for the ASNT NDT Level II MT exam?

Most working candidates need 4 to 8 weeks at 45 to 60 minutes a day. Book your exam once your Readiness Score has stayed at 80 or higher for about a week.

Can I take the ASNT NDT Level II MT exam online?

No. ASNT NDT Level III exams are taken in person, on a computer, at Pearson VUE test centers or ASNT Authorized Exam Centers. Format: computer-based multiple choice with an on-screen calculator. asnt does not publish whether any reference is supplied during these exams; confirm with asnt. this prep covers only the written general and specific exams, not the employer's visual acuity, practical or job-specific exams. Check ASNT's current exam information for the rules.

What score do I need to pass the ASNT NDT Level II MT exam?

Not published by ASNT for this exam. ASNT says its criterion-referenced cut scores are typically 70% to 80%. Both the General and the Specific exam must be passed, so aim for 80% or higher on each in practice. The exam has two multiple-choice exams: general 50 items and specific 40 items (general industry or pressure equipment sector) and a time limit of general 2 hours; specific 2 hours (4 hours in total).

What are the most tested topics?

The outline covers mt principles and theory, use and care of mt equipment and accessories, mt techniques and demagnetization, interpreting, evaluating and documenting results, codes, standards, specifications and procedures, specific exam: general industry, specific exam: pressure equipment. Use the free practice test to see which ones you need most.

The premium ASNT NDT Level II MT study path

Premium ASNT NDT Level II MT prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 50 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 7 topics

Your step-by-step study path

  1. 1
    MT Principles and Theory9 key notes, 115 flashcards, then 450 practice questions in 18 sets of 25
    Notes free with an account
  2. 2
    Use and Care of MT Equipment and Accessories9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  3. 3
    MT Techniques and Demagnetization9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  4. 4
    Interpreting, Evaluating and Documenting Results9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  5. 5
    Codes, Standards, Specifications and Procedures8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  6. 6
    Specific Exam: General Industry8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  7. 7
    Specific Exam: Pressure Equipment8 key notes, 110 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  8. Final step: 6 full mock exams50 questions each, timed like test day. Pass them, then book your exam.
    Premium

Get every note, flashcard and question

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a retake fee, for the certification that lets you approve procedures and certify technicians
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

Summarized from ASNT's official candidate information and the rules cited, checked October 2026. Confirm current requirements with ASNT Certification Services LLC (American Society for Nondestructive Testing).

Start the free test