The exam at a glance

Questions135 multiple-choice questions (some are unscored pretest items)
Time4 hours
Passing scoreNot published per exam. ASNT sets criterion-referenced cut scores (Angoff or IRT) and says its exams are typically in the 70% to 80% range; aim for 80% or higher in practice
FormatComputer-based multiple choice with an on-screen calculator. ASNT does not publish reference-material rules on its exam page; confirm with ASNT. Certification also needs the NDT Level III Basic exam
Certifying bodyASNT Certification Services LLC (American Society for Nondestructive Testing)
Test providerPearson VUE test centers and ASNT Authorized Exam Centers (in person, computer-based); no practical exam

Mind map: the whole exam on one screen

ASNT NDT Level III ET
ET Principles and Theory
Standard depth formulaPhase lag at one standard depthCurrent density at three standard depthsEffect of doubling frequency on standard depth
ET Equipment, Probes and Accessories
Fill factor of an internal bobbin probeCoil type that cancels gradual changesCoil type best for gradual wall lossAdvantage of reflection (driver-pickup) probes
Techniques, Reference Standards and Calibration
Frequency for second-layer cracksUsual lift-off display directionPurpose of a multifrequency mixCommon artificial flaw for surface crack standards
RFT, ACFM and Other Electromagnetic Techniques
7 key facts
Interpreting, Evaluating and Documenting Results
7 key facts
Codes, Standards, Specifications and Procedures
7 key facts
ET Training and Certification Programs
7 key facts
Free with an account

Read the complete ASNT NDT Level III ET study notes for “ET Principles and Theory”

Our first full set of comprehensive notes, about 15 minutes of reading: Induction and impedance · Skin effect and standard depth · Variables that change the signal · Ferromagnetic materials, demagnetization and POD, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

1. ET Principles and Theory

Domain 1 of ASNT's ET outline from 9 January 2027 (and eddy current principles in the earlier outline): induction, impedance, skin effect, and the material and coupling variables, plus demagnetization and POD studies. ASNT does not publish domain weights.

Key facts

  • An AC coil induces eddy currents in a conductor; their secondary field opposes the primary and changes the coil impedance (resistance and inductive reactance).
  • Standard depth δ = 1 ÷ √(πfμσ). In practice δ (mm) ≈ 660 ÷ √(f × %IACS × μr), with f in Hz. Halving δ needs four times the frequency.
  • Current density falls as e^(-x/δ): 37% at 1δ, about 14% at 2δ and 5% at 3δ. Phase lag is x/δ radians: 57° at 1δ.
  • Variables that change impedance: conductivity, permeability, frequency, geometry, lift-off or fill factor, and discontinuities.
  • Ferromagnetic materials have high and variable permeability, which masks flaw signals; DC magnetic saturation suppresses it, and parts are then demagnetized with a reversing, decreasing field.
  • Eddy currents flow parallel to the coil windings, so flaws parallel to the current flow (and to the surface, such as laminations) are hard to detect.
  • Probability of detection (POD) studies relate flaw size to detection rate; a90/95 is the flaw size detected 90% of the time with 95% confidence.

Flashcards

Standard depth formulaδ = 1 ÷ √(πfμσ).
Phase lag at one standard depth1 radian, about 57°.
Current density at three standard depthsAbout 5% of the surface value.
Effect of doubling frequency on standard depthDepth falls to 1 ÷ √2, about 71%.

Exam tip: Most ET physics questions are one formula. Write δ and its frequency dependence on your scratch paper at the start.

2. ET Equipment, Probes and Accessories

Domain 2 of the new outline: selecting instruments, probes, cables and scanners and evaluating equipment and contractor capability.

Key facts

  • Probe types: surface (pancake, pencil), encircling (OD) coils, internal bobbin coils, and arrays of many coils for C-scan imaging.
  • Absolute coils respond to gradual changes; differential coils cancel slow changes and highlight small, abrupt flaws.
  • Bridge (impedance) probes use the same coil to drive and sense; reflection (driver-pickup) probes use separate coils and give a wider frequency range and better subsurface response.
  • Fill factor for encircling coils is (part diameter ÷ coil diameter)²; for internal probes, (probe diameter ÷ tube ID)².
  • Shielded probes limit the field spread, reducing edge effect and fastener interference.
  • Instruments display signals on the impedance plane; multifrequency instruments allow channel mixing.
  • Cable length and type affect probe impedance and noise; change cables only if the procedure allows and recalibrate.

Flashcards

Fill factor of an internal bobbin probe(Probe diameter ÷ tube ID)².
Coil type that cancels gradual changesDifferential.
Coil type best for gradual wall lossAbsolute.
Advantage of reflection (driver-pickup) probesWider frequency range and better subsurface response.

Exam tip: Pick the probe by flaw shape: abrupt flaws suit differential coils; gradual changes suit absolute coils.

3. Techniques, Reference Standards and Calibration

Domain 6 of the new outline: designing and selecting reference standards, choosing and validating techniques, and standardizing equipment.

Key facts

  • Reference standards must match the test material's conductivity, permeability and nominal size, with artificial flaws (EDM notches, drilled or flat-bottom holes, grooves) of known size.
  • Frequency choice balances penetration against sensitivity: high frequency for surface cracks, low frequency for subsurface layers and thick sections.
  • Phase is set so lift-off appears in a fixed direction (usually horizontal) and flaw signals rotate away from it.
  • Multifrequency mixing removes unwanted signals such as support plates, deposits or probe wobble.
  • Edge effect is controlled with shielded probes and scan paths at constant distance from the edge.
  • Conductivity measurement uses standards traceable in %IACS; coating thickness on nonferrous metals uses the lift-off effect.
  • Calibration is checked at the start, at intervals set by the procedure and at the end; failure means re-examining everything since the last good check.

Flashcards

Frequency for second-layer cracksLow frequency, with a larger probe.
Usual lift-off display directionHorizontal on the impedance plane.
Purpose of a multifrequency mixCancel unwanted signals such as support plates.
Common artificial flaw for surface crack standardsEDM notch of known depth.

Exam tip: When asked how to improve detection, check frequency first, probe second and signal processing third.

Test yourself on these topics

Take the free 15-question ASNT NDT Level III ET test, then save your results to unlock your Readiness Score and the mistakes bank.

Start the free test

4. RFT, ACFM and Other Electromagnetic Techniques

Remote field testing and alternating current field measurement are listed separately in the outline for exams before 9 January 2027 and remain ET techniques under the new outline; pulsed eddy current and arrays round out the toolset.

Key facts

  • RFT uses a low-frequency exciter and a detector about two to three tube diameters away, in the remote field zone.
  • The RFT field passes through the tube wall twice, so ID and OD wall loss give similar responses in ferromagnetic tubes.
5 more key facts, 9 key notes, 115 flashcards and 425 practice questions for this topic are in premium.

Flashcards

RFT detector spacingAbout two to three tube diameters from the exciter.

Exam tip: Choose the technique from the material and access: ferromagnetic tubes favor RFT, coated ferritic welds favor ACFM.

5. Interpreting, Evaluating and Documenting Results

Domain 3 of the new outline: managing inspection operations, reviewing results, separating relevant from nonrelevant indications and reporting.

Key facts

  • Relevant indications come from discontinuities; nonrelevant ones come from lift-off, wobble, geometry, supports, deposits, dents or permeability changes.
  • A signal along the lift-off phase is from probe spacing, not a flaw.
5 more key facts, 8 key notes, 115 flashcards and 425 practice questions for this topic are in premium.

Flashcards

Signal with the same phase as lift-offProbe lift-off or wobble, nonrelevant.

Exam tip: Always ask what else could cause the signal before calling it a flaw: lift-off, geometry and material changes come first.

6. Codes, Standards, Specifications and Procedures

Domain 4 of the new outline: reviewing client requirements, interpreting codes, developing and reviewing procedures and applying acceptance criteria.

Key facts

  • ASME Section V Article 8 covers eddy current examination of tubular products and other applications in its appendices.
  • Article 8 tubing standards must be made from the same material specification and nominal size as the tubes examined.
5 more key facts, 8 key notes, 115 flashcards and 425 practice questions for this topic are in premium.

Flashcards

ASME code article for eddy currentSection V Article 8.

Exam tip: In procedure review questions, look for anything that changes the eddy current response: material, size, frequency, probe.

7. ET Training and Certification Programs

Domain 5 of the new outline: managing ET personnel and OJT, developing training, writing and administering exams and assessing exam quality.

Key facts

  • Under SNT-TC-1A, the employer's written practice, approved by its NDT Level III, sets training, experience, exams and certification.
  • Level I and II qualification uses general, specific and practical exams; SNT-TC-1A recommends at least 70% on each and an 80% composite when equally weighted.
5 more key facts, 8 key notes, 110 flashcards and 425 practice questions for this topic are in premium.

Flashcards

Specimens for an ET practical examKnown, documented discontinuities typical of the work.

Exam tip: Program questions reward the documented, objective and traceable choice.

How to pass

  • 135 questions in 4 hours is about 107 seconds each. Standard depth, fill factor and frequency calculations should take under a minute.
  • Check your exam date: before 9 January 2027 the outline lists eddy current, remote field testing and ACFM separately; from that date ASNT uses six task-based domains.
  • Learn standard depth both ways: δ = 1 ÷ √(πfμσ), and in practice δ (mm) ≈ 660 ÷ √(f × %IACS × μr). Frequency scales with 1 ÷ δ².
  • The new outline adds Level III program duties (training, exams, OJT) and equipment selection, so expect judgment questions as well as physics.

Frequently asked questions

How long should I study for the ASNT NDT Level III ET exam?

Most working candidates need 4 to 8 weeks at 45 to 60 minutes a day. Book your exam once your Readiness Score has stayed at 80 or higher for about a week.

Can I take the ASNT NDT Level III ET exam online?

No. ASNT NDT Level III exams are taken in person, on a computer, at Pearson VUE test centers or ASNT Authorized Exam Centers. Format: computer-based multiple choice with an on-screen calculator. asnt does not publish reference-material rules on its exam page; confirm with asnt. certification also needs the ndt level iii basic exam. Check ASNT's current exam information for the rules.

What score do I need to pass the ASNT NDT Level III ET exam?

Not published per exam. ASNT sets criterion-referenced cut scores (Angoff or IRT) and says its exams are typically in the 70% to 80% range; aim for 80% or higher in practice. The exam has 135 multiple-choice questions (some are unscored pretest items) and a time limit of 4 hours.

What are the most tested topics?

The outline covers et principles and theory, et equipment, probes and accessories, techniques, reference standards and calibration, rft, acfm and other electromagnetic techniques, interpreting, evaluating and documenting results, codes, standards, specifications and procedures, et training and certification programs. Use the free practice test to see which ones you need most.

The premium ASNT NDT Level III ET study path

Premium ASNT NDT Level III ET prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 135 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 7 topics

Your step-by-step study path

  1. 1
    ET Principles and Theory9 key notes, 115 flashcards, then 450 practice questions in 18 sets of 25
    Notes free with an account
  2. 2
    ET Equipment, Probes and Accessories9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  3. 3
    Techniques, Reference Standards and Calibration9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  4. 4
    RFT, ACFM and Other Electromagnetic Techniques9 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  5. 5
    Interpreting, Evaluating and Documenting Results8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  6. 6
    Codes, Standards, Specifications and Procedures8 key notes, 115 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  7. 7
    ET Training and Certification Programs8 key notes, 110 flashcards, then 425 practice questions in 17 sets of 25
    Premium
  8. Final step: 6 full mock exams135 questions each, timed like test day. Pass them, then book your exam.
    Premium

Get every note, flashcard and question

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · less than a retake fee, for the certification that lets you approve procedures and certify technicians
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • One ASNT Level III exam of your choice: Basic, UT, RT or MT
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: NDT formula sheet, discontinuity atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

Summarized from ASNT's official candidate information and the rules cited, checked October 2026. Confirm current requirements with ASNT Certification Services LLC (American Society for Nondestructive Testing).

Start the free test